Sharp NEC Display Solutions
Wall Calibrator

ReadMe Information for Mac OS

Version 2.0.00 - Build 180118 - January 18 2018

Contents:

 

About Wall Calibrator

Wall Calibrator system will automatically adjust multiple displays used in a video wall so that the color characteristics closely match, thereby creating the visual illusion of a single large display.

 

Release Notes

Known issues

Required Minimum Firmware version:

The following display models require a minimum firmware version in order to work correctly with Wall Calibrator. The firmware version can be checked in the Display Settings dialog on the Status tab, or by using the Tools menu - "Verify Monitor Firmware..." function. Please contact NEC if your display needs to be updated to newer firmware.

Model Minimum Firmware Version
P402
1.017
P462
1.017
P552
1.017
V422
1.017
V462
1.017
V551
1.017
V651
1.017
X461S
1.017
X551S
1.017
X551UN
1.017
LCD4020
1.1.09
LCD4620
1.1.09
LCD5220
1.1.09
LCD6520
1.1.09
M40, M40B, and M40-2
1.1.09
M46, M46B, and M46-2
1.1.09
M401
1.0.18
M461
1.0.18
P401
1.0.18
P461
1.0.18
X461HB
1.2.00

Posterized image when using LUT:

In certain cases the screen image may appear posterized temporarily while the LUTs are being updated, when using firmware up to, and including, version 1.017 on the following display models: P402, P462, V422, V462, V551, V651, X461S, X551S, X551UN. If the posterizing continues after the LUTs have finished being updated, reset the monitor power.

Analog Auto Bias/Gain Setup function on the Video tab in Display Settings:

This function does not work with firmware prior to, and including, version 1.017 on the following display models: P402, P462, P552, V422, V462, V551, V651, X461S, X551S, X551UN. If it is necessary to use this function, it must be accessed from the Advanced OSD menu. Note that adjusting via the OSD is faster than via software.

Schedule Function with LCDxx20 or Mx0 series displays:

When using the Schedule function from the Display Settings dialog, it is not possible to set the Input setting to "Last Input" using the software. Either set the Input setting to a specific input, or use the IR Remote to set the setting on the OSD.

Schedule Function with X461UN and X461HB displays with firmware earlier than version 1.2.00:

When using the Schedule function from the Display Settings dialog, it is not possible to set the Picture Mode setting to "Last Input" using the software. Either set the Picture Mode setting to a specific mode, or use the IR Remote to set the setting on the OSD. The firmware version can be checked in the Display Settings dialog on the Status tab.

X-Rite i1Pro or i1Monitor color sensor: If using the X-Rite i1Pro or i1Monitor -

X-Rite i1Display Pro:

This version includes support for the X-Rite i1Display Pro color sensor.
The X-Rite ColorMunki Display device introduced in mid-2011 is not supported.
The NEC SpectraSensor Pro is based on the X-Rite i1Display Pro sensor and is supported. Note that this sensor may not be supported by non-NEC software.

 

Supported Operating Systems

This version of Wall Calibrator requires Mac OS X version 10.10 or higher.

PowerPC based Macs are not supported. Only Intel based Macs are supported.

If using RS232 to connect the Mac to the displays, a USB to RS232 adapter can be used. Be sure to install the drivers for the adapter as native support is not included in Mac OS.

 

Supported Display Monitors

Note:

Wall Calibrator supports the following display monitor models:

 

Supported Color Sensors

Wall Calibrator supports the following color sensors:

 

Support and Troubleshooting

If you are having problems with Wall Calibrator detecting the display monitor, please be sure to read the User's Guide included with the software. It contains a FAQ and Troubleshooting guide.

For additional technical support, please visit the Sharp NEC Display Solutions Wall Calibrator support page. A feedback form is available for direct assistance with Wall Calibrator.

 

Revision History

V1.0.00: July 27 2009

V1.0.10: November 16 2009

V1.0.12: March 31 2010

V1.0.20: December 15 2010

V1.0.22: July 1 2011

V1.0.23: November 23 2011

V1.0.24: January 18 2012

V1.0.25: March 28 2012

V1.1.00: November 6 2013

V1.1.10: June 30 2014

V1.1.20: May 12 2015

V1.1.22: December 21 2015

V1.1.30: March 8 2016

V1.1.40: January 27 2017

V2.0.00: January 11 2018

Copyright

This file and all of the Wall Calibrator software is Copyright (C) 2009-18 Sharp NEC Display Solutions, Ltd.

CryptoPP (www.cryptopp.com) Compilation Copyright (c) 1995-2006 by Wei Dai. All rights reserved. This copyright applies only to this software distribution package as a compilation, and does not imply a copyright on any particular file in the package.